labcomplete AIS-Schnittstelle
0.1.0 - ci-build
Österreich
labcomplete AIS-Schnittstelle - Local Development build (v0.1.0) built by the FHIR (HL7® FHIR® Standard) Build Tools. See the Directory of published versions
| Draft as of 2026-10-29 |
{
"resourceType" : "MessageDefinition",
"id" : "request-updated",
"text" : {
"status" : "generated",
"div" : "<div xmlns=\"http://www.w3.org/1999/xhtml\"><p class=\"res-header-id\"><b>Generated Narrative: MessageDefinition request-updated</b></p><a name=\"request-updated\"> </a><a name=\"hcrequest-updated\"> </a><p><b>url</b>: <a href=\"MessageDefinition-request-updated.html\">MessageDefinition RequestUpdated</a></p><p><b>version</b>: 0.1.0</p><p><b>name</b>: RequestUpdated</p><p><b>title</b>: RequestUpdated</p><p><b>status</b>: Draft</p><p><b>date</b>: 2026-10-29</p><p><b>publisher</b>: medcom GmbH</p><p><b>contact</b>: medcom GmbH: <a href=\"https://www.medcom.at\">https://www.medcom.at</a>,<a href=\"mailto:support@medcom.at\">support@medcom.at</a></p><p><b>description</b>: </p><div><p>labcomplete schickt den Stand einer Anforderung; das AIS quittiert nur.</p>\n</div><p><b>jurisdiction</b>: <span title=\"Codes:{urn:iso:std:iso:3166 AT}\">Österreich</span></p><p><b>copyright</b>: </p><div><p>© 2026 medcom GmbH. Alle Rechte vorbehalten.</p>\n</div><p><b>event</b>: <a href=\"CodeSystem-ais-event.html#ais-event-request-updated\">Nachrichten der AIS-Schnittstelle: request-updated</a> (Rückschrieb)</p><p><b>category</b>: Notification</p><h3>Focus</h3><table class=\"grid\"><tr><td style=\"display: none\">-</td><td><b>Code</b></td><td><b>Profile</b></td><td><b>Min</b></td><td><b>Max</b></td></tr><tr><td style=\"display: none\">*</td><td>ServiceRequest</td><td><a href=\"StructureDefinition-ais-request.html\">Anforderung</a></td><td>1</td><td>1</td></tr></table><p><b>responseRequired</b>: Never</p></div>"
},
"url" : "https://fhir.labcomplete.at/ais/v1/MessageDefinition/request-updated",
"version" : "0.1.0",
"name" : "RequestUpdated",
"title" : "RequestUpdated",
"status" : "draft",
"date" : "2026-10-29",
"publisher" : "medcom GmbH",
"contact" : [
{
"name" : "medcom GmbH",
"telecom" : [
{
"system" : "url",
"value" : "https://www.medcom.at"
},
{
"system" : "email",
"value" : "support@medcom.at"
}
]
}
],
"description" : "labcomplete schickt den Stand einer Anforderung; das AIS quittiert nur.",
"jurisdiction" : [
{
"coding" : [
{
"system" : "urn:iso:std:iso:3166",
"code" : "AT",
"display" : "Österreich"
}
]
}
],
"copyright" : "© 2026 medcom GmbH. Alle Rechte vorbehalten.",
"eventCoding" : {
"system" : "https://fhir.labcomplete.at/ais/v1/CodeSystem/ais-event",
"code" : "request-updated"
},
"category" : "notification",
"focus" : [
{
"code" : "ServiceRequest",
"profile" : "https://fhir.labcomplete.at/ais/v1/StructureDefinition/ais-request",
"min" : 1,
"max" : "1"
}
],
"responseRequired" : "never"
}